CA ESP Workload Automation r55 Solutions Patches - CA Technologies
{{search ? 'Close':'Search'}}

CA Workload Automation ESP Edition r5.5
Solutions & Patches

The Solutions & Patches listed from this page are all fixes that were moved over from the Support.Cybermation.com website. This page will not be updated with new fixes.
All Solutions/Fixes created after November 02, 2007 can be found at the Download Center located at
https://support.ca.com/irj/portal/SolutionSearch.

Name Type Size Date Released Description Prerequisites
SU02899.zip ZIP 297 KB 11/02/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: CDB84DB6

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF22445
IPv6 enablement for CA ESP Workload Automation (ESP Agent
Agent communication and Workstation Server).
IPv6 implementation for Network Delivery Services (NDS).

DF23122
Corrections to CA ESP Workload Automation listener and connect
retry and recovery following a TCP/IP outage or TCP/IP failure.
Network Delivery Services (NDS) listener retry capability added.
Network Delivery Services (NDS) listener and connect default
retry interval set to 60 seconds, but retry failure messages
issued every 5 minutes.

DF23219
Optional HOME or HOME(<host_or_ip>) operand added to the
following Network Delivery Services (NDS) commands -

NETWORK START LISTENER
NETWORK SET CONNECTIONS
NETWORK START CONNECTION

When NETWORK START LISTENER HOME or HOME(<host_or_ip>) is
specified, NDS will bind to the default or specified local IP
address before listening for incoming connection requests.
When NETWORK SET CONNECTIONS HOME or HOME(<host_or_ip>) is
specified, NDS will by default bind to the default or specified
local IP address when connecting to a remote NDS partner.
When NETWORK START CONNECTION HOME or HOME(<host_or_ip>) is
specified, NDS will bind to the default or specified local IP
address when connecting to a remote NDS partner.

The NETWORK SET CONNECTIONS and NETWORK START CONNECTION commands
also provide an optional NOHOME operand to override a previous
HOME or HOME(<host_or_ip) specification.

DF23222
Correction to very rare occurrence of abend S0C4 due to stray
garbage value in an access register while processing a Network
Delivery Services (NDS) transmission of an internodal job
tracking record.

DF23401
If NETWORK QUEUE DISPLAY command is issued with conflicting
operands, send command response message 3359E to command issuer.

DF23411
CA ESP Workload Automation master could hang if stopped
immediately after initiating Network Delivery Services (NDS)
connection.

TYPE/RESTART:
Warm restart ESP Workload Manager subsystems.

*/.
None
SU02929.zip ZIP 4 KB 11/02/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: C3DA8D7A

USERS AFFECTED:
ESP Workstation Server users.

PROBLEM(S) FIXED:
DF23338
If a TCP/IP outage occurs, Workstation Server's TCP listener
will retry every minute until successful or until Workstation
Server is stopped.
Retry failure error messages are issued every five minutes.

TYPE/RESTART:
Restart Workstation Server.

*/.
None
SU02919.zip ZIP 11 KB 10/25/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: 7B1F8DC2

USERS AFFECTED:
All CA ESP Workload Automation users.

PROBLEM(S) FIXED:
DF16293
This PTF reduces the likelihood of a S0D6 abend in CA ESP
Workload Automation if an operator issues an AUX_AS CANCEL or
AUX_AS BOUNCE command to cancel or cancel-and-restart the
Encore auxiliary address space without first issuing an
ENCPARM QUIESCE command.

DF22990
This PTF prevents a U2508 abend in the TSO session of users
who access CA ESP Workload Automation through CommServ (CA ESP
Workload Automation Communication Server). The abend
occurred if ESP Encore 3.1 was installed and a CSF user
chose a job for restart. (CommServ access is selected when
the name of an APPC side information entry is specified in
the XSYSTEM argument of the command that calls program ESP
from a TSO session or from a batch job.) A subsystem
request extension block is now treated uniformly with or
without CommServ.

TYPE/RESTART:
Warm start CA ESP Workload Automation.
TSO users: exit and reenter the CA ESP Workload Automation interface.

*/.
None
SU02938.zip ZIP 3 KB 10/25/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: 53B17674

USERS AFFECTED:
Users that perform backup of event data set.

PROBLEM(S) FIXED:
DF23428
CA ESP Workload Automation cannot backup a suspended
(closed) event data set. Instead it remembers the backup
request and performs a backup when event data set
is available again (opened). Due to a program error,
corruption of memory was possible in this situation
resulting in a CA ESP Workload Automation abend.
This PTF fixes the abend.

TYPE/RESTART:
Warm restart of CA ESP Workload Automation.

*/.
None
SU03062.zip ZIP 5 KB 10/25/07 /*
PRODUCT: CA ESP Workload Automation Version 5.5

USERS AFFECTED:
Users who use ESP internal security option (non-SAF).

PROBLEM(S) FIXED:
DF23405
CA ESP Workload Automation subsystem abended with S0C4 ABEND at
CYBJS036 + x'7B4' when listing events with a wildcard in the group
prefix name and the internal CA ESP Workload Automation security
protocol was in use (SAFCLASS command was omitted from ESPPARM).

TYPE/RESTART:
Warm restart CA ESP Workload Automation subsystems.

*/ .
None
SU03063.zip ZIP 9 KB 10/25/07 /*
PRODUCT: CPE Version 5.1

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23410
One of CA ESP Workload Automation's threads was mistakenly removed
from the Ready queue and as a result not executed.

TYPE/RESTART:
Warm restart ESP Workload Manager subsystems.

*/ .
None
SU02915.zip ZIP 6 KB 10/15/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: 12DAEA26

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23113
If an error occurred extending the NETQUEUE data set to its
maximum size, an abend S01D-CF050311 would occur on the next
attempt to extend the data set, due to an attempt to extend its
data space beyond its maximum size.

TYPE/RESTART:
Warm restart ESP Workload Manager subsystems.

*/.
None
SU02934.zip ZIP 56 KB 10/15/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: D719F527

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23356
Application Monitor line commands not cleared after execution.

DF23383
ISPF S0C4 when selecting Application Monitor (ESP option 'A')
if subsystem name was less than 4 characters.

TYPE/RESTART:
Exit & reenter CA ESP Workload Automation in TSO/ISPF.

*/.
None
SU03058.zip ZIP 64 KB 10/15/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: DD4827E6

USERS AFFECTED:
All users of the Consolidated Status Facility.

PROBLEM(S) FIXED:
DF23355
If a user has never issued a PR command in CSF,
some random problems may have been encountered the first
time that the PR command is used within CSF. This is due
to an incorrect setting in an ISPF variable that contains
CSF presentation settings.

TYPE/RESTART:
Recycle the affected TSO session(s).

*/.
None
SU03060.zip ZIP 78 KB 10/15/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: A296C658

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23363
Application JOB DOCMEM() parameter is ignored when a Job
(with no RUN statement) is selected via a SELECT statement.
This fix does not apply to currently running Applications.

DF23368
Avoid truncation of 2611I Alertdef 'not defined' message.

DF23384
An error message 4667E is issued when Workstation Server requests
a PDS data set but no member name is specified. If a similar
request is made against a PDS/E data set, no error message is
issued and the resulting output is invalid.

DF23385
Abend S0C4 in CYBXJ000 when Workstation Server requests
information about an application with many job dependencies.

DF23393
Pre-requisite to ESP Encore 3.1 CA-LMP licensing PTF SU02895.
Has no effect on ESP Encore 3.1 licensing when applied without
PTF SU02895.

TYPE/RESTART:
Warm start CA ESP Workload Automation
and Workstation Server. TSO users restart ISPF.

*/.
None
SU02792.zip ZIP 10 KB 10/09/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: 10BAD329

USERS AFFECTED:
ESP Workstation Server users.

PROBLEM(S) FIXED:
DF23310
Add the following ESP commands to ESP Workstation Server:
CONSOLE, MSG, MSGTYPE.
The commands may be specified in the WSSPARM initialization file
or as an operand of the system MODIFY (F) command. They have the
same syntax as the equivalent ESP Workload Manager commands, and
give ESP Workstation Server the same console message routing
capabilities as ESP Workload Manager.

TYPE/RESTART:
Restart Work Station Server.

*/.
None
SU03035.zip ZIP 3 KB 10/09/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: 7F1240BB

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23245
Do not allow CYBESUDI RESYNCH to run on proxy. The
following message will be generated: ESP6902E RESYNCH
process is not allowed on proxy.

TYPE/RESTART:
No restart required.

*/.
None
SU03038.zip ZIP 29 KB 10/09/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: F79A087F

USERS AFFECTED:
All CA ESP Workload Automation users.

PROBLEM(S) FIXED:
DF23268
When doing a LISTAPPL command, certain conditions can
cause the output to be terminated with an ESP1164W
message. This PTF allows the command to continue
processing without terminating.

TYPE/RESTART:
Re-run the affected batch job or restart the affected TSO session.

*/.
None
SU03044.zip ZIP 30 KB 10/09/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: 0AD3D660

USERS AFFECTED:
All users of the SELECT/DESELECT SUBAPPL statement.

PROBLEM(S) FIXED:
DF23256
If the subappl name in the SELECT/DESELECT statement is coded
in lower or mixed case, message ESP2013E is issued.

TYPE/RESTART:
Warm start CA ESP Workload Automation.
Restart Workstation Server.
TSO users reenter CA ESP Workload Automation.

*/.
None
SU03052.zip ZIP 29 KB 09/28/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: 1D05176B

USERS AFFECTED:
All users of the LISTAPPL command.

PROBLEM(S) FIXED:
DF23361
LISTAPPL COMMAND CAUSED ICH408I USER error message. A request
for a specific generation of an application inadvertantly
did a security check on all generations, e.g.

LISTAPPL APPLNAME.10

Only generation 10 should be checked in this case.

TYPE/RESTART:
Apply the PTF and restart CA ESP Workload Automation as well as
any affected TSO sessions.

*/.
None
SU03054.zip ZIP 48 KB 09/28/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: 455B16BA

USERS AFFECTED:
All SAP_JOB users.

PROBLEM(S) FIXED:
DF23123
Disable MODIFYJOB command for SAP JOBCOPY jobs.

TYPE/RESTART:
Warm start CA ESP Workload Automation and Workstation Server.
TSO users restart ISPF.

*/.
None
SU03057.zip ZIP 10 KB 09/28/07 /*

PRODUCT: CA ESP Workload Automation Version 5.5

CHECKSUM: B15E6737

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23381
Abend D23 if SEND command specifies an invalid Console name
or ID.

TYPE/RESTART:
Warm start CA ESP Workload Automation and Workstation Server.
TSO users restart ISPF.

*/.
None
SU02894.zip ZIP 30 KB 09/14/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: D89E5FCB

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF22444
CA licensing support added for ESP Workload Manager 11.3 and
above.
Applying this PTF to ESP Workload Manager 5.5 or below will have
NO effect on the Cybermation licensing mechanism used by these
versions.

TYPE/RESTART:
Warm restart ESP Workload Manager subsystems.
Restart ESP Workstation Server.
Restart ESP TSO/ISPF clients.

*/.
None
SU02920.zip ZIP 55 KB 09/14/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: E9DCF076

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23183
Application Monitor PF-Keys missing ("PF??" on ApplMon panels).
This could happen after entering ApplMon for the very first
time (within any TSO session) if the PF-Keys are subsequently
reset via a previously open ISPF split-screen session.

DF23282
This PTF corrects an "ESP133E SUBSYSTEM REQUEST ERROR CODE
4-28" when attempting to enter the Application Monitor
(option 'A') from the main ESP Workload Manager menu.

TYPE/RESTART:
Exit and reenter ESP Workload Manager in TSO/ISPF.

*/.
None
SU03045.zip ZIP 8 KB 09/14/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 2B1334A5

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF22809
SIMULATION processing should be similar for all EXTERNAL jobs,
irrespective of their job types. For example, an extraneous
error message 4141E is issued if an EXTERNAL File_Trigger job
does not have an AGENT defined, in SIMULATION. These EXTERNAL
jobs attempt to display their AFM, however they are not real
executable jobs. This fix prevents extraneous error messages
during simulation.

TYPE/RESTART:
Warm restart of ESP Workload Manager.
TSO users reenter ESP Workload Manager environment.
Restart Workstation Server.

*/.
None
SU03049.zip ZIP 27 KB 09/14/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 144FDDA6

USERS AFFECTED:
All users of the SIMULATE command in batch.

PROBLEM(S) FIXED:
DF23353
If the SIMULATE command is used in batch for an event
whose application contains a loop in successor jobs,
the following message will be issued:

ESP2014E SUCCESSOR LOOP DETECTED

The command will then terminate with a return code of 0.
This PTF will cause the batch program to return an appropriate
return code of 4.

TYPE/RESTART:
Re-run the batch job.

*/.
None
SU02771.zip ZIP 20 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: A213336D

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23182
When an ESP Agent Receiver is suspended due to a TCP/IP error,
retry indefinitely rather than only 12 times.

DF23223
ESP Agent Receiver retry time following a TCP/IP error is reduced
from 5 minutes to one minute. However, ESP agent receiver retry
error messages are issued every 5 minutes.

DF23258
AGENTRCV DEFINE command corrected to accept HOME operand without
explicit DNS host name or IP address specification.

TYPE/RESTART:
Restart ESP Workload Manager master subsystem.

*/.
None
SU02814.zip ZIP 20 KB 11/09/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: 706FE0AB

USERS AFFECTED:
ALL Users

PROBLEM(S) FIXED:
16016437
Long messages may be truncated when they go to SYSLOG.
With this PTF long messages are broken up into multiple
lines of 71-character length and then output to SYSLOG.

TYPE/RESTART:
Warm restart of ESP Workload Manager.

*/.
SU02911.zip ZIP 8 KB 11/09/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: 7F4431B9

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF22952
If USERMOD 63 is set, then system commands issued by the VS
command in ESP Workload Manager events and/or procedures will
not execute under the ESP Workload Manager's event owner's
SAF security token. This restores pre ESP Workload
Manager 5.4 behavior.

TYPE/RESTART:
Warm start ESP Workload Manager.

*/.
SU02913.zip ZIP 26 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: C17DD76E

USERS AFFECTED:
CA-TCPaccess users.

PROBLEM(S) FIXED:
DF23068
If CA-TCPaccess is the stack used to perform TCP/IP operations
and ESP Workload Manager uses NDS (Network Delivery Services) for
internodal job tracking and/or remote Encore, the ESP Workload
Manager master hung while initializing.

TYPE/RESTART:
Warm restart ESP Workload Manager subsystems.

*/.
None
SU02922.zip ZIP 17 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: CA69B6FF

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23244
This PTF corrects a memory leak causing abend 878-10
when a CALENDAR statement specifies two calendars but
the first calendar does not exist.

TYPE/RESTART:
Warm restart of ESP Workload Manager.
TSO users reenter ESP Workload Manager environment.
Restart Workstation Server.

*/.
None
SU02925.zip ZIP 14 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 5DCDBF08

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23249
PURGAPPL hangs ESP Workload Manager.

TYPE/RESTART:
Warm start ESP Workload Manager master system.

*/.
None
SU02927.zip ZIP 4 KB 11/09/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: E06890DF

USERS AFFECTED:
All

PROBLEM(S) FIXED:
DF23264
This PTF corrects a memory leak in ESP Workload
Manager when ESP Encore 3.1 is installed.

TYPE/RESTART:
Warm restart ESP Workload Manager.

*/.
SU03010.zip ZIP 36 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 44A0D3C7

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23127
Satisfy requests for resources with zero quantity
without checking available count.

TYPE/RESTART:
Warm restart ESP Workload Manager.

*/.
None
SU03019.zip ZIP 72 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 483DF375

USERS AFFECTED:
All

PROBLEM(S) FIXED:
DF23176
New application remains in applwait state if it was created
while the previous generation was completing.

DF23195
Job cancelled from input queue (no start time) shows wrong
statistics in LJS display.

DF23083
Abend0C4 on receipt of job end notification from dSeries Manager.

TYPE/RESTART:
Warm start ESP Workload Manager.

*/.
None
SU03020.zip ZIP 11 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 483DF375

USERS AFFECTED:
All

PROBLEM(S) FIXED:
DF23184
Jobs with full names inserted into an active application are
given duplicate generated qualifiers. A LISTAPPL command for
a specific job may display more than one job because it uses
generated qualifiers for job lookup.

TYPE/RESTART:
Warm start ESP Workload Manager.

*/.
None
SU03023.zip ZIP 9 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 0FE966F7

USERS AFFECTED:
All users of ESP Workstation.

PROBLEM(S) FIXED:
DF23203
A side effect of PTF SU02811 shortened the list of calendar
entry information and caused ESP Workstation a problem
displaying the entries.
For example, with 3 special days defined, the incorrect
display in page mode showed:

ls
CALENDAR: SPECIAL
NAME: BONUS_NEWYEARS
START: 00.00 ON WEDNESDAY JANUARY 2ND, 2008
START: 00.00 ON THURSDAY JANUARY 3RD, 2008
START: 00.00 ON FRIDAY JANUARY 4TH, 2008
---- 3 DATES LISTED ----

whereas it should have showed:

ls
CALENDAR: SPECIAL
NAME: BONUS_NEWYEARS
START: 00.00 ON WEDNESDAY JANUARY 2ND, 2008
NAME: BONUS_NEWYEARS
START: 00.00 ON THURSDAY JANUARY 3RD, 2008
NAME: BONUS_NEWYEARS
START: 00.00 ON FRIDAY JANUARY 4TH, 2008
---- 3 DATES LISTED ----

TYPE/RESTART:
Warm start ESP Workload Manager & Workstation server.

*/.
None
SU03025.zip ZIP 49 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 622AA4E2

USERS AFFECTED:
All users

PROBLEM(S) FIXED:
DF22305
When the RESDFLT command is used with one of its keyword and
without a resource name, then the previous resource name is
mistakenly kept instead of being deleted.

This fix also prevent a storage corruption when the resource
name is specified as double quotes only.

DF23226
Do not uppercase password in ESP Workstation/Web user interface
logon, pass it to a SAF product as is.
This is necessary if mixed case password support is on.

TYPE/RESTART:
Warm restart ESP Workload Manager subsystems.
Restart ESP Workstation Server.
TSO users re-enter ESP.

*/.
None
SU03026.zip ZIP 42 KB 11/09/07 /*

PRODUCT: CPE Version 5.1

CHECKSUM: 8E939BE4

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23206
ESP4251E error message causes ABEND0C4 of ESP Workload
Manager.

TYPE/RESTART:
Warm start of ESP Workload Manager.

*/.
SU03028.zip ZIP 15 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 37F3D731

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23227
If two jobs with the same name are submitted simultaneously,
ESP Workload Manager may lose track of the second job,
under some circumstances.

TYPE/RESTART:
Warm restart of ESP Workload Manager.
TSO users reenter ESP Workload Manager environment.
Restart Workstation Server.

*/.
None
SU03032.zip ZIP 12 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 0E2EDB24

USERS AFFECTED:
All users of large applications.

PROBLEM(S) FIXED:
DF23233
If a large application is generated and the user issues
a LISTAPPL command, that command can result in an 0C4 abend.

After this PTF is installed, such a commend will cause the
following message to be issued:

ESP1143E APPLBUFF TOO SMALL TO RETRIEVE APPLICATION

The size of the APPLBUF initialization parameter should be
increased and the ESP started task should be restarted.

TYPE/RESTART:
Restart ESP Workload Manager.

*/.
None
SU03036.zip ZIP 8 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 9EBAE56E

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23248
Abend0C4 when a job's predecessor list reaches 4K in length.

TYPE/RESTART:
Warm start ESP Workload Manager.

*/.
None
SU03039.zip ZIP 16 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 81CF56CB

USERS AFFECTED:
All.

PROBLEM(S) FIXED:
DF23271
With procedure caching on, if a WOB has a LONGNAME parameter,
all WOB specific statements, such as AGENT, CMDNAME, etc are
ignored, and SUBERROR is generated.

TYPE/RESTART:
Warm restart ESP Workload Manager.
Restart ESP Workstation Server.
TSO users reenter ESP Workload Manager environment.

*/.
None
SU03042.zip ZIP 13 KB 09/11/07 /*

PRODUCT: ESP Workload Manager Version 5.5

CHECKSUM: 24863866

USERS AFFECTED:
All users of the "L" command with the PRINT option.

PROBLEM(S) FIXED:
DF22676
After the "L" command is processed with the PRINT(dsn) option,
the data set is left allocated to ESP Workload Manager.
This fix frees the data set.

TYPE/RESTART:
Restart ESP Workload Manager.
Logoff and logon to TSO session.

*/.
None

Chat with CA

Just give us some brief information and we'll connect you to the right CA Expert.

Our hours of availability are 8AM - 5PM CST.

All Fields Required

connecting

We're matching your request.

Unfortunately, we can't connect you to an agent. If you are not automatically redirected please click here.

  • {{message.agentProfile.name}} will be helping you today.

    View Profile


  • Transfered to {{message.agentProfile.name}}

    {{message.agentProfile.name}} joined the conversation

    {{message.agentProfile.name}} left the conversation

  • Your chat with {{$storage.chatSession.messages[$index - 1].agentProfile.name}} has ended.
    Thank you for your interest in CA.


    How Did We Do?
    Let us know how we did so that we can maintain a quality experience.

    Take Our Survey >

    Rate Your Chat Experience.

    {{chat.statusMsg}}

agent is typing